Details
Description
novAA® 400 P — the PC-controlled fully automated compact spectrometer for flame, graphite furnace and hydride/HydreA technology.
- 8 lamp changer for maximum automation and sample throughput
- Single and double beam available
- D2 background correction
- Integrated RFID Tool for working with coded lamps
- Integrated super lamp power supply for best analytical performance
- Integrated High-end Vision Tool for best observation and control of sample injection and sample drying in the graphite tube
- Direct analysis of solid samples
Transverse-heated graphite furnace
The future-oriented furnace heating concept, which can cope with a variety of samples, including complex matrices and refractory elements
Variable sample feeding techniques
This is unique: Smooth feeding of liquids and solids (direct analysis), and fast change between both techniques
Software
Software package ASpect® LS
ASpect® LS offers both routine operation and multifarious development and optimization facilities. It allows comprehensive control, monitoring and recording of all processes run in the spectrometer and its accessories.
Advanced user-friendliness
- Simple, routine handling and great flexibility
- Clearly laid-out user interface makes method development on the screen fast and simple
- Ready-to-use cookbook programs facilitate getting into method development
Automated optimization
The automatic optimizing routine simplifies the adaptation of methods to an unknown matrix. All parameters and functions are automatically monitored and controlled.
The software automatically optimizes and adapts flame and graphite tube parameters, such as Zeeman magnetic field strength in the 2field or 3field mode, atomizing and pyrolysis temperature, roll-over effect, and control of the 3field mode.
Data postprocessing the easy way
- Diverse export routines in compatible data formats
- Linking into networks or data transfer into LIMS system is not a problem either
Quality Control and GLP
- ASpect® LS is compliant with all requirements of GLP: All analytical data are accessible, their accuracy is ascertained and documented
FDA 21 CFR Part 11
- Conformity to FDA 21 CFR Part 11 is ensured
- Comprehensive user management, an electronic signature facility, the Audit Trail and many more features satisfy the requirements of FDA 21 CFR Part 11
Accessories
solid AA® — Direct solid AAS
- SSA 6 z — manual solid sampling system
- SSA 600 — fully automatic solid sampling system with integrated microbalance
- SSA 600L — fully automatic solid sampling system with integrated microbalance and liquid dosing accessory
Autosampler systems for flame, hydride and atomic fluorescence technique
- AS-F and AS-FD — autosamplers for flame technique
- Make the routine analysis of standards and samples almost fully automatic
HydrEA
Coupling of graphite furnace and hydride technique
Modular hydride systems
- Flow injection as well as batch mode available
- Systems can be upgraded at any time — it “grows” with the lab’s requirements
- Easy exchange between all configurations
- Color-coded tubing connections and flow scheme — easy replacement of consumables
- Upgrade to HydrEA, easy exchange between mercury/hydride and HydrEA
- Special mercury accessories
- Fast Baseline Return drastically reduces the measurement time for mercury
- Fully compliant with all applicable DIN, ISO, EPA and ASTM methods for mercury and hydride analysis
“Segmented Flow Star SFS 6”
- Two-way module for software-controlled metering of smallest volumes via time control
- Reduces risk of burner head slit blocking due to continuous intensive rinsing
- Minimizes necessity of cleaning intervals of the sample introduction system
- Minimizes problems while analyzing samples with high matrix contents (high acid and salt contents, protein etc.)
- Improves base line stability of the spectrometer (constant flame temperature)
- Can additionally be used for the analysis of organic solvents
- Complete maintenance free operation
Scraper
- Allows software controlled periodical cleaning during flame warm up and during sample measurements
- Ensures stable flame conditions
Applications
Our atomic absorption spectrometers are used in nearly every field of instrumental analysis. Among the most important ones there are:
- Environment/water/waste water
- Food/agriculture
- Geology/mining
- Metallurgy/galvanization
- Material analysis
- Semi-conductor technology
- Chemistry
- Polymer industry
- Elektronics
- Energy
- Clinical chemistry/medicine/hygiene/health care
- Refineries/petrochemistry
- Pharmacy
- Cosmetics
Application Notes
- AA_EA_02_06_e .pdf | 150.15 kB
Determination of Pb in Glucose and Fe and Al in Water
- AA_FL_02_09_e .pdf | 71.40 kB
Determination of Pb and Cd in Seaweed
- AA_FL_02_10_e .pdf | 147.10 kB
Determination of Zn in Insoline
Downloads
- Brochure novAA series (English) .pdf | 728.73 kB
Inquiry Form
FAQ Question
Shipping & Delivery
Our partner Toll Ipec performs all Australian wide deliveries via safe road transport. Transport times depend on your location. In general you can expect delivery in maximum two days for metro areas in Queensland, Victoria, NSW and ACT. Deliveries to Western Australia and South Australia can take up to one week.
International deliveries are done with our partner Fedex or a standard cargo carrier. Shipments can take one to two weeks depending on your location.
For items, which are not currently on stock, we offer the option of express import and shipment at additional cost. Please contact us if your order is urgent.
For international deliveries please request individual quotations via our quote request function in the shopping cart after selecting your location and entering your address details.
Shipping Rates
Australia
Orders less than $1000 in value
Flat rate - $30
Orders greater than $1000 in value:
Flat rate - Free
New Zealand
Orders less than $1000 in value:
Flat rate - $120
Orders greater than $1000 - $5000 in value:
Flat rate - $250
Orders greater than $5000 in value :
Flat rate - Free
International Shipping
Please request individual quotations via the shopping cart